Unlike the basic meters people use at home, industrial models are designed to be more accurate, much more durable, and meet strict safety standards CAT III 1000V.
They provide the detailed and exact readings needed to find and fix problems in complex equipment, such as motor drives, factory automation systems, electrical panels, and large machines.
Aside from safety, accuracy, The main focus of CEM DT-9987 is having the specific features needed for industrial work. like Low Pass filter, loZ, low ohm measurement, TrendCapture graphically display, etc.
The industrial multimeter is essential for electrical technicians, industrial maintenance engineers, automation specialists, and power system operators.
Safety:
IEC61010-1 CAT IV 600V / CAT III 1000V
UL, CSA, and TÜV listed for maximum safety and global compliance
Applications:
-- Motor and drive troubleshooting
-- Control panel maintenance
-- PLC system diagnostics
-- Transformer testing
-- Predictive maintenance
Motor and drive troubleshooting
Use an industrial multimeter to identify the root cause of these common issues:
- Motor Won't Start:Verify control and supply voltages; test winding integrity.
- Overheating:Measure phase balance and current draw; check for voltage fluctuations.
- Drive Tripping:Inspect DC bus and output phase voltages; monitor supply stability.
- Phase Imbalance:Note: Voltage imbalance greater than 2–3% drastically shortens motor lifespan.
PLC system diagnostics
In PLC systems, an industrial multimeter is essential for checking power supplies, verifying I/O signals, testing wiring, and confirming sensor outputs. It is one of the most fundamental tools used in automation maintenance and troubleshooting.
TrendCapture graphically display
TrendCapture shows you a quick graph of your logged data, so you can easily spot any issues.
Helps capture intermittent faults, analyze signal quality, and monitor trends over time without a separate recorder
True RMS, high accuracy
accurately measures AC voltage/current regardless of waveform shape / non-linear loads.
DCV basic accuracy 0.025%.
Noise filtering capability , Low Pass filter
low pass filter mode which filters out high frequency noise created by a variable frequency drives (VFD) and gives you an accurate reading
loZ
low input impedance prevents false readings due to “ghost voltage”.
Practical being used to verify if a wire is actually energized, Troubleshooting floating neutral or control wiring
low ohm measurement
Useful for measuring and comparing differences in motor winding resistance or contact resistance.
mV (millivolt) measurement
practical for measuring small signals, testing electronic components
4-20mA process loop measurement
troubleshooting 4-20 mA signal loops from a sensor
Logging function
The device has a built-in logging feature with plenty of memory,
You can look at the data as a graph directly on the device.
wireless connection, data share (PC / App)
Technicians can monitor readings remotely, which is especially useful when panels must be closed to operate or are in hazardous areas .
Features
tool application |
Industrial applications, e.g. Motor and drive troubleshooting / Control panel maintenance / PLC system diagnostics |
high safety ratings |
IEC/EN 61010: CAT IV 600 V / CAT III 1000 V |
|
|
|
True RMS |
Industrial systems often use non-linear loads (VFDs, inverters, motors).True RMS ensures accurate readings even with distorted waveforms |
High Accuracy |
DCV basic accuracy 0.025% |
Measurement functions |
Measurement of AC/DC voltage, current, resistance, capacitance, frequency, temperature, duty cycle, and continuity, etc. |
|
|
|
Noise Filtering for Industrial Environments |
Low Pass Filter (LPF) precisely measure the electronic signal-to-noise equipment voltage and frequency |
LoZ |
low input impedance prevents false readings due to “ghost voltage”. |
Relative mode : |
eliminates the test line impedance existed in low resistance or capacitance measurement. |
low ohm |
Moto winding and low ohm 50 ohm measurement range |
additional functions |
support Max/Min; Micoamps; mV (millivolt) measurement Peak Capture function: records transient signal as fast as 250uS |
|
|
|
Advanced Diagnostics |
TrendCapture™ display, Helps capture intermittent faults, analyze signal quality, and monitor trends over time without a separate recorder . |
Specialized Functions |
4-20mA loop measurement; Temperature measurement via thermocouple Addresses the specific needs of control panels, such as checking sensors (temperature) or troubleshooting 4-20 mA signal loops |
|
|
|
Data Logging |
a built-in logging feature |
Wireless Connectivity |
Bluetooth support PC / smartphone, data transfer, process and report |
|
|
|
Display |
Large 50,000 count, 320 x 240 TFT color LCD display |
IP Rating |
IP67 dust and water proof. 2 meter drop protection rated for outdoor use |
Ease of use |
Modern digital multimeters, Easy-to-Use |
certification |
CE, TüV certification |
warranty, certification
All products are CE , GS and TüV certificated.
Based on robust quality and customers’ satisfaction, generally we provide 3 years warranty .
Data Sheet
Data Sheet -- Czechia
Data Sheet -- English
Data Sheet -- French
Data Sheet -- German
Data Sheet -- Italiano
Data Sheet -- Polish
Data Sheet -- Spanish
Data Sheet -- Swedish
Data Sheet -- Turkish
Manuals
User Manual -- Czechia
User Manual -- English
User Manual -- French
User Manual -- German
User Manual -- Italiano
User Manual -- Polish
User Manual -- Spanish
User Manual -- Swedish
User Manual -- Turkish